MIL-DTL-24308/24H
Inches
mm
Inches
mm
Inches
mm
.005
0.13
.104
2.64
.247
6.27
.010
0.25
106
2.69
.251
6.38
.015
0.38
.112
2.84
.283
7.19
.030
0.76
.115
2.92
.302
7.67
.040
1.02
.120
3.05
.340
8.64
.062
1.57
.125
3.18
.395
10.03
.065
1.65
.135
3.43
.484
12.29
.070
1.78
.220
5.59
.507
12.88
.092
2.34
.594
15.09
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Pin diameter .041/.039 (1.04/0.99 mm) diameter pin for arrangements (see MIL-DTL-24308, appendix A)
A-1-1, A-2-1, A-3-1, A-4-1 and A-5-1. Pin diameter .0305/.0295 (.775/.749 mm) diameter for
arrangements A-1-2, A-2-2, A-3-2, A-4-2, and A-5-2.
4. Copyright notice. All information disclosed in this military specification sheet which is or may be
copyrighted by ITT Cannon Electric is reproduced herein with the expressed permission of the
copyright owner.
5. The 90 ° bracket shall be one piece flame resistant glass-filled nylon, polyester or two piece metal and nylon of
which the metal pieces shall be coated with a material in accordance with IPC-CC-830.
6. The 90 ° bracket shall be furnished as an integral part of the connector assembly.
7. Spacers will be supplied with connectors (not attached to the connector).
8. Layout shown for reference only to locate CL. See applicable insert arrangement.
9. Requirement for contact retention shall be 3.5 lbs. for right angle printed circuit board mount connectors.
Connectors may be fastened to board for test.
10. Dimensions are .150 (3.81 mm) minimum full pin diameter extension (sizes 3 through 6) and .159 (4.04 mm)
minimum full pin diameter extension (sizes 1 and 2).
11. Unless otherwise specified, tolerance is ± .010 inch (0.25 mm).
12. In the event of a conflict between the text of this specification sheet and the references cited herein, the text of
this specification sheet shall take precedence.
13. Referenced Governments documents of the issue listed in ASSIST Online database at https://assist.daps.dla.mil/
specified in the solicitation form a part of this standard to the extent specified herein.
14. Indentation on the ends of the termination side of the shell, for the purpose of securing the insulator in the shell,
is permitted. This may result in the "F" dimension being undersized in these areas. However the "F" dimension
shall be maintained for the remainder of the connector.
15. For classes M, N and D use table I for applicable dash numbers.
FIGURE 1. Shell, plug, printed wiring board type Continued.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business