MIL-DTL-2726/35C
REQUIREMENTS
Dimensions and configuration: See figure 1.
Contact resistance: When tested as specified in accordance with MIL-DTL-2726, the voltage
the voltage drop shall not exceed 20 millivolts. Measured between
the end of a 12.000-inch length of AWG number 6 stranded copper wire,
properly connected to the test plug, and the connection stud of the
receptacle.
Uncoupling force: Minimum of 8 pounds; maximum of 20 pounds.
High Impact shock: Disengagement of the test plug from its test receptacle under High Impact
shock shall not be considered as a failure.
Contact hardness: Minimum of Rockwell 76B.
Mating plug: MIL-DTL-2726/33, Part or Identifying Number (PIN) M23726/33-001 red;
PIN M2726/33-002 black.
Design: Panel hole - .096 inch diameter.
Panel thickness .062 inch to .250 inch.
Material: Body and cap - rubber, in accordance with ASTM-D2000, M2AC 710 A13E034 or
plastic, in accordance with ASTM-D5948 type MAI-60.
Electrical rating: 40-ampere, 125-volt, single pole.
PIN: M2726/35-001 (red) symbol 1213.2, M2726/35-002 (black) symbol 1214.4.
Contact finish: Silver plate.
Verification
Verification shall be as specified in MIL-DTL-2726 and table I herein. The first article and
conformance inspections shall consist of the inspections as specified in table I, in the order shown.
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business