MIL-DTL-3655/23B
9
Insulation resistance: 5 x 10 ohms, minimum.
Contact insulator captivation: Applicable.
Salt spray (corrosion): Applicable.
Connector durability: Applicable.
Contact resistance (milliohms, maximum):
Initial
After environment
Inner conductor contacts:
3.5
4.7
Outer conductor contacts:
.4
Not applicable
Dielectric withstanding voltage: 1,500 V rms, minimum, at sea level.
Vibration, high frequency: Applicable.
Shock (specified pulse): Applicable.
Temperature cycling: Applicable.
Humidity: Applicable, but no measurement shall be made at high humidity.
8
Insulation resistance shall be at least 2 x 10 ohms within 5 minutes after removal from
the humidity chamber.
Cable retention force: Not applicable.
Coupling nut retention: Not applicable.
Part or Identifying Number (PIN): M3655/23-0001.
Qualification: Not required.