MIL-DTL-38999/9B
Dimensions
Shell
X
Y
R
S
J
M
T
K
±.020
±.010
size
(TP)
(TP)
BSC
+.010
dia
+.015
-.015
+.010
-.000
-.005
77°
113°
9
.3595
.938
67°
123°
11
.406
1.031
63°
127°
13
.453
1.125
61°
129°
15
.085
.727
.128
.4845
1.219
.567
65°
125°
17
.531
1.312
65°
125°
19
.578
1.438
65°
125°
21
.625
1.562
69°
121°
23
.115
.697
.147
.6875
1.688
69°
121°
25
.750
1.812
Inches
mm
Inches
mm
Inches
mm
Inches
mm
.005
0.13
.3539
9.13
.625
15.88
1.125
28.58
.010
0.25
.406
10.31
.632
16.05
1.219
30.96
.015
0.38
.453
11.51
.6875
17.46
1.312
33.32
.063
1.60
.4845
12.31
.697
17.70
1.438
36.53
.085
2.16
.531
13.49
.727
18.47
1.562
39.67
.115
2.92
.567
14.30
.750
19.05
1.688
42.88
.128
3.25
.578
14.68
.938
23.83
1.812
46.02
.147
3.73
.602
15.29
1.031
26.19
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. The gage features for GG shall be .010 (0.25 mm) smaller than the MMC size at basic location.
4. Flange is solid.
5. Dummy receptacles are used when unmated plugs must be protected.
FIGURE 1. Dummy receptacle, finishes B, T, X and Z - Continued.