MIL-DTL-39024/1D
REQUIREMENTS:
Design and construction:
Dimensions and configuration: See figure 1 and table I.
Terminals: Shall be capable of being wired with two type E, AWG 20 wires in accordance with
NEMA-HP3. Configuration shall be specified on figure 1 and table I.
Test probe: .080 ± .001 inch in diameter and .438 inch (min) length.
Contact current rating: 5 amperes (max).
Contact resistance: A test probe in accordance MIL-DTL-39024 shall be fully inserted in the connector.
With a current of 5 amperes, potential drop shall be measured between the connector terminal and the
extreme end of the solder cup on the test probe. Measured values shall be 20 millivolts (max).
Dielectric withstanding voltage (at sea level):
Test voltage shall be as follows:
Dash numbers
Volts, rms (60 Hz)
3,000
-01 thru -10
2,500
-11 thru -20
3,000
-21 thru -30
2,500
-31 thru -40
Insertion and withdrawal forces:
Insertion force: 4.5 pounds (max).
Withdrawal force: 0.4 pound (min).
Identification marking:
Part or Identifying Number (PIN): M39024/1-(dash number from table I).
Operating conditions:
Operating voltage is as follows:
Dash numbers
At sea level
At 50,000 feet
-01 thru -10 and -21 thru -30
2,000 volts rms, 60 Hz
525 volts rms, 60 Hz
-11 thru -20 and -31 thru -40
1,800 volts rms, 60 Hz
500 volts rms, 60 Hz
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business