MIL-DTL-39024/12E
TABLE I. Design and identification data.
Insulation
Dimensions
1/
Dash
number
Number
A
B
C
D
E
F Dia
G
H
Color
in accordance
±.010
± .002
Dia
Dia
Dia
with
FED-STD-595
(0.25)
(0.05)
17875
White
.054
.219
.074
.185
.037
.047
.317
.453
-01
(1.37)
(5.56)
(1.88)
(4.70)
(0.94)
(1.19)
(8.05)
(11.51)
11105
Red
"
"
"
"
"
"
"
"
-02
17038
Black
"
"
"
"
"
"
"
"
-03
10075
Brown
"
"
"
"
"
"
"
"
-04
14110
Green
"
"
"
"
"
"
"
"
-05
12246
Orange
"
"
"
"
"
"
"
"
-06
15123
Blue
"
"
"
"
"
"
"
"
-07
13655
Yellow
"
"
"
"
"
"
"
"
-08
16187
Gray
"
"
"
"
"
"
"
"
-09
27144
Purple
"
"
"
"
"
"
"
"
-10
---
Natural
"
"
"
"
"
"
"
"
-11
-12
.390
.265
.046
.023
.068
.149
.172
.040
White
17875
(9.91)
(6.73)
(1.17)
(0.58)
(1.73)
(3.78)
(4.37)
(1.02)
-13
"
"
"
"
"
"
"
"
Red
11105
-14
"
"
"
"
"
"
"
"
Black
17038
-15
"
"
"
"
"
"
"
"
Brown
10075
-16
"
"
"
"
"
"
"
"
Green
14110
-17
"
"
"
"
"
"
"
"
Orange
12246
-18
"
"
"
"
"
"
"
"
Blue
15123
-19
"
"
"
"
"
"
"
"
Yellow
13655
-20
"
"
"
"
"
"
"
"
Gray
16187
-21
"
"
"
"
"
"
"
"
Purple
27144
-22
"
"
"
"
"
"
"
"
Natural
---
1/ Metric equivalents are in parentheses.
REQUIREMENTS:
Design and construction:
Dimensions and configuration: See figure 1 and table I.
Insulation: Material shall be polytetrafluoroethylene in accordance with ASTM D1710.
Operating temperature: -65°C to +200°C.
Test probe: Connectors shall be .500 inch (minimum) length and accept test probe tips as follows:
Probe dia. (±.001)
Dash numbers
-01 thru 11
.080 inch
-12 thru 22
.040 inch
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business