MIL-DTL-642E
4.6.4 Contact resistance (see 3.6.3). Plugs shall be tested in accordance with method 307 of MIL-STD-
202. The following details shall apply:
Method of connection Applicable mating jack (see table IV).
a.
b.
Test current 100 ± 2 milliamperes direct current.
c.
Maximum open-circuit test voltage Approximately 6 volts.
d.
Number of activations prior to measurement Six, using applicable mating jack (see table IV).
e.
Number of test activations One.
f.
Number of measurements per activation Measure between each plug terminal and the
corresponding jack terminal, at the point of normal connection.