MIL-PRF-31031B
TABLE VI. Inspection level for group B.
Lot size
Sample size
VSWR sample size
1
ALL
1
to
5
1
5
6
to
15
2
5
16
to
50
3
5
51
to
90
3
11
91
to
150
3
13
151
to
280
3
16
281
to
500
19
5
501
to
1,200
23
5
1,201
to
3,200
29
5
3,201
to
10,000
35
5
10,001
to
35,000
40
8
35,001
and over
4.5.1.3.2 Disposition of sample units. Sample units which have passed all the group B inspection may
be delivered on the contract or purchase order, if the lot is accepted. Any connector or connector part
deformed or otherwise damaged during testing shall not be delivered on the contract or order.
4.5.2 Periodic inspection. Periodic inspection shall consist of group C. Except where the results of
these inspections shown noncompliance with the applicable requirements (see 4.5.2.1.4), delivery of
products which have passed groups A and B shall not be delayed pending the results of these periodic
inspections.
4.5.2.1 Group C inspection. Group C inspection shall consist of the inspections specified in table VII,
in the order shown. Group C inspection shall be made on sample units selected from inspection lots
which have passed the groups A and B inspection.
18
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business