MIL-PRF-39012/60D
Dielectric withstanding voltage at sea level: In accordance with test procedure EIA - 364-20, 1,000
Volts rms.
Vibration, high frequency: In accordance with test procedure EIA - 364-28, test condition IV.
Shock: In accordance with test procedure EIA - 364-27, condition G.
Thermal shock: In accordance with test procedure EIA - 364-32, 5 cycles, except test high temperature
shall be +200°C.
Humidity: In accordance with test procedure EIA - 364-31. No measurements at high humidity.
Insulation resistance shall be at least 200 mega ohms within 5 minutes after removal from humidity.
Corona level:
Voltage: 250 volts minimum.
Altitude: 70,000 feet.
RF high potential withstanding voltage:
Voltage and frequency: 670 Volts rms at 5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
Coupling mechanism retention force: Not applicable.
RF leakage: Not applicable.
RF insertion loss: Not applicable.
Group qualification: See table I.