MIL-PRF-39012/61D
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
3.0
4.0
Outer contact:
2.0
Not applicable
Dielectric withstanding voltage at sea level: In accordance with EIA - 364-20,1,000 volts rms, minimum.
Vibration, high frequency: In accordance with EIA - 364-28, test condition IV.
Shock: In accordance with EIA - 364-27, condition G.
Thermal shock: In accordance with EIA - 364-32, 5 cycles, except test high temperature shall be
+200°C.
Humidity: In accordance with EIA - 364-31. No measurements at high humidity. Insulation resistance
shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona level:
Voltage: 250 volts minimum.
Altitude: 70,000 feet.
RF high potential withstanding voltage:
Voltage and frequency: 670 volts rms at 5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
Coupling mechanism retention force: Not applicable.
RF leakage: Not applicable.
RF insertion loss: Not applicable.
Group qualification: See table I.