MIL-PRF-39012/62D
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
7.0
8.0
Outer contact:
2.0
Not applicable
Dielectric withstanding voltage at sea level: In accordance with test procedure EIA- 364-20 1,000 volts
rms, minimum.
Vibration, high frequency: In accordance with test procedure EIA- 364-28 test condition IV.
Shock: In accordance with test procedure EIA- 364-27 condition G.
Thermal shock: In accordance with test procedure EIA- 364-32 condition I, 5 cycles, except test high
temperature shall be +200°C.
Humidity: In accordance with test procedure EIA- 364-31 method IV. No measurements at high
humidity. Insulation resistance shall be at least 200 megohms within 5 minutes after removal from
humidity.
Corona level:
Voltage: 250 volts minimum.
Altitude: 70,000 feet.
RF high potential withstanding voltage:
Voltage and frequency: 670 volts rms at 5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
Coupling mechanism retention force: Not applicable.
RF leakage: Not applicable.
RF insertion loss: Not applicable.
Group qualification: See table I.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business