MIL-PRF-39012/77B
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: In accordance with MIL-STD-202, method 302, test condition B, 1,000 megohms
minimum.
Center contact retention:
Axial force: 6 pounds minimum axial force from mating end; 4.0 pounds from opposite end.
Radial torque: 3 inch-ounces, minimum.
Resistance to test prod damage: Not applicable.
Salt atmosphere (corrosion): In accordance with MIL-STD-202 method 101, test condition B.
Voltage standing wave ratio (VSWR): Not applicable.
Connector durability: 500 cycles minimum at 12 cycles per minute maximum. The connector shall
meet mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
6.0
8.0
Outer contact:
1.0
Not applicable
Dielectric withstanding voltage at sea level: In accordance with MIL-STD-202, method 301. 1,000 V
rms, minimum at sea level.
Vibration, high frequency: In accordance with MIL-STD-202, method 204, test condition D.
Shock: In accordance with MIL-STD-202, method 213, test condition C.
Thermal shock: In accordance with MIL-STD-202, method 107, test condition B.
Moisture resistance: Not applicable.
Corona level: Not applicable.
RF high potential withstanding voltage:
Voltage and frequency: 600 V rms, tested at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
Coupling mechanism retention force: Not applicable.
RF leakage: Not applicable.
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business