MIL-PRF-49142/8D
RF high potential withstanding voltage:
800 V rms, between center conductor and intermediate conductor.
200 V rms, between intermediate conductor and outer conductor at 5 MHz to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force (for cable .200 inch (5.08 mm) to .325 inch (8.25 mm) outside dimension), 40
pounds (177.93 N) minimum.
Coupling mechanism retention force: 100 pounds (444.82 N) minimum.
Rise time degradation: 400 picoseconds maximum. (Not applicable to connectors using twin conductor
cables.)
Connector durability: 500 cycles minimum at 12 cycles per minute maximum.
Part or Identifying Number (PIN): M49142/08- (dash number from table I). CAUTION: A NICKEL
PLATED BODY COMBINATION IS AVAILABLE. THIS COMBINATION IS NOT FOR USE IN
APPLICATIONS WHERE PASSIVE INTERMODULATION GENERATION (PIM) MAY BE A
CONCERN.
Group qualification: See table II.
Cross-reference of cables: See table III.
Retention of qualification: See table IV.
6
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business