INCH-POUND MS18192G
5 January 2011
SUPERSEDING MS18192F
1 June 1983
DETAIL SPECIFICATION SHEET
SHIELD, ELECTRICAL CONNECTORS FOR
7, 9, 14, 20, 26, 34, 42, 50 AND 75
CONTACT CONNECTORS
Reinstated after 10 July 2009 and may be used for new and existing designs and acquisitions.
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-28748.
.120 +.004 DIA
-.001
CL 2 HOLES
CL D B CL
CLAMP SHAPE OPTIONAL MAY BE ATTACHED TO SIDE OF SHEILD
CL
(SEE NOTE 8)
SIDE S
TOP T
.19 +.003 DIA.
2 HOLES
(FOR USE WITH
LONG JACKSCREWS)
.62 MAX.
(SEE NOTE 7) CL
OPTIONAL
SLOTS A
CL
.62 MAX. C
Shield designator |
Shield and shield clamp location |
Connector size (number of contacts) |
A min max |
B ± .016 (0.41 mm) |
C ± .016 (0.41 mm) |
D ±.005 (0.13 mm) |
F Minimum cable opening square inch |
MS18192-T7 MS18192-S7 |
top opening side opening |
7 |
1.18 (29.97) 1.35 (34.29) |
1.220 (30.99) |
.437 (11.10) |
.906 (23.01) |
.18 (4.57) |
MS18192-T8 MS18192-S8 |
top opening side opening |
9 |
1.18 (29.97) 1.35 (34.29) |
1.312 (33.32) |
.437 (11.10) |
1.000 (25.40) |
.10 (2.54) |
MS18192-T1 MS18192-S1 |
top opening side opening |
14 |
1.18 (29.97) 1.35 (34.29) |
1.250 (31.75) |
.500 (12.70) |
.938 (23.83) |
.19 (4.83) |
MS18192-T14 MS18192-S14 |
top opening side opening |
18 |
1.18 (29.97) 1.35 (34.29) |
1.190 (30.23) |
.630 (16.00) |
1.000 (25.40) |
.22 (5.59) |
MS18192-T2 MS18192-S2 |
top opening side opening |
20 |
1.18 (29.97) 1.35 (34.29) |
1.562 (39.67) |
.500 (12.70) |
1.250 (31.75) |
.22 (5.59) |
MS18192-T9 MS18192-S9 |
top opening side opening |
26 |
1.18 (29.97) 1.35 (34.29) |
1.625 (41.28) |
.640 (16.26) |
1.312 (33.32) |
.22 (5.59) |
FIGURE 1. Shields for 7, 9, 14, 18, 20, 26, 34, 42, 50, and 75 contact positions.
AMSC N/A FSC 5935
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business