MS90558G
Non-grounding assemblies: finish N
Shell size |
Shell main key positions |
2 wire |
|
28 V dc |
|
28 |
N {105°) |
32 |
N {105°) |
44 |
N {105°) |
48 |
N {105°) |
52 |
N {105°) |
Grounding assemblies: Finishes, conductive
Shell size |
Shell main key positions |
||||||
60 Hz and 400 Hz {see note 1) |
|||||||
1 0 |
3 0 |
3 0 {see note 2) |
|||||
2 wire |
3 wire |
4 wire |
3 wire |
||||
120 V |
240V |
120/240 V |
120/208 V |
240/416 V |
277/480 V |
450/480 V |
|
28 |
4 {120°) |
5 {135°) |
4 {120°) |
4 {120°) |
5 {135°) |
6 {150°) |
--------- |
32 |
4 {120°) |
5 {135°) |
4 {120°) |
4 {120°) |
5 {135°) |
6 {150°) |
--------- |
44 |
4 {120°) |
--------- |
4 {120°) |
4 {120°) |
5 {135°) |
6 {150°) |
1 {60°) |
48 |
-------- |
--------- |
4 {120°) |
4 {120°) |
5 {135°) |
6 {150°) |
--------- |
52 |
-------- |
--------- |
4 {120°) |
4 {120°) |
5 {135°) |
6 {150°) |
--------- |
NOTES:
1. Discrimination of 60 Hz and 400 Hz assemblies is accomplished by alternate positioning of inserts.
See applicable insert drawing for keying.
2. For Navy ground support equipment use only. Arrangement 44-51, 44-52 and 44-56 are not applicable.
3. Shell main key positions 2 and 3 not used.
4. Dimensions are in inches. Metric equivalents are given for information only.
5. For protective cover, see MS90564.
6. F dimension applies only when the coupling nut is fully engaged.
FIGURE 1. Plug - Continued.