W-C-596/151C
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Unless otherwise specified, tolerance is ±.005 (0.13 mm) on all decimals and ±5° on angles.
4. For mounting dimensions see figure II configuration A of the basic specification.
FIGURE 1. Configuration and dimensions - Continued. REQUIREMENTS:
Design and configuration: See figure 1.
Ratings:
Voltage: 120 volts, 1 phase. Current: 30 amperes. Frequency: 400 hertz.
Vibration: Method 204 of MIL-STD-202, test condition B (WC596/151-2 only). Shock: Method 213 of MIL-STD-202, test condition I (WC596/151-2 only). Mating connector: W-C-596/152
Part or Identifying Number (PIN): The PIN consists of the prefix W-C, the basic specification number, the specification sheet number, and the style number.
W-C- 596 /151 -1
Style number (see table I) Specification sheet number Specification number
W-C Prefix
TABLE I. Dash number.
Dash no. |
Supersedes style |
Description |
1 |
||
2 |
ruggedized |
Changes from previous issue. Marginal notations are not used in the revision to identify changes with respect to the previous issue due to the extensiveness of the changes.
Referenced documents. In addition to W-C-596, this document references the following: W-C-596/152
MIL-STD-202
2