W-C-596/39C
REQUIREMENTS:
Design and configuration: General grade (see figure 1). Dimensions: Shall conform to NEMA WD 6, configuration 18-60P. Armored construction: Not acceptable.
Mating face: Dead-front construction.
Ratings:
Voltage: 3 phase wye, 120/208 volts. Current: 60 amperes.
Frequency: 50/60 hertz.
Mating connector: W-C-596/38
Strain relief: Accommodate cable diameter 1.070 - 1.255 inches.
Part or Identifying Number (PIN): W-C-596/39- (dash number from table I). Supersession and cross reference: See table II.
TABLE I. Dash number.
Dash no. |
Supersedes style |
Description |
1 |
U22 |
Straight plug |
2 |
U21 |
Angle plug |
TABLE II. Supersession and cross reference.
Active Government PIN |
Superseded numbers |
|||
CAGE 1/ 21873 |
CAGE 08556 |
CAGE 71183 |
CAGE 04009 |
|
W-C-596-39/1 |
7303 |
5517 |
||
W-C-596/39-2 |
3865 |
1482 |
8362-ANP |
4516 |
1/ CAGE is the Commercial and Government Entity code which is assigned and maintained by
Defense Logistics Information Service (DLIS) in Battle Creek, MI.
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business