MIL-DTL-3655/9E
Contact resistance (milliohms, maximum):
Initial
After environment
Inner conductor contacts:
2.67
3.80
Outer conductor contacts:
.38
Not applicable
Braid to body
.20
Not applicable
Dielectric withstanding voltage: 1,500 V rms, minimum, at sea level.
Vibration, high frequency: Applicable.
Shock (specified pulse): Not applicable.
Temperature cycling: Applicable.
Humidity: Applicable, but no measurement shall be made at high humidity. Insulation resistance
shall be at least 2 x 108 ohms within 5 minutes after removal from the humidity chamber.
Cable retention force: 75 pounds, minimum.
Coupling nut retention: Applicable.
Part or Identifying Number (PIN): M3655/9-1060.
First article shall apply as follows: First article test inspection shall be performed in accordance with
the requirements outlined in the latest revision of MIL-DTL-3655.
Changes from previous issue. Marginal notations are not used in this revision to identify changes with
respect to the previous issue due to the extent of the changes.
Referenced documents. In addition to MIL-DTL-3655, this document references the following:
ASTM-B700
SAE-AS28775