MIL-DTL-38999/33E
mm
Inches
mm
Inches
0.13
.005
4.24
.17
0.25
.01
5.84
.23
0.51
.02
7.72
.30
1.57
.06
7.92
.31
2.00
.08
9.55
.38
2.50
.098
12.20
.48
2.54
.100
15.70
.62
FIGURE 1. Protective cover, receptacle, all classes Continued.
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Materials:
Cover -
Classes C, F, G, R, W and X: Impact extruded or machined aluminum alloy.
Classes P, T and Z: Impact extruded or machined aluminum alloy.
Classes H, K, N, S and Y: Corrosion resistant steel.
Classes J and M: High performance resin in accordance with MIL-DTL-38999.
(Class F is inactive for new design.)
Gasket -
Silicone elastomer.
Ring -
Corrosion resistant steel, passivated, 1.020 mm (.04 inches) maximum thickness.
Rope -
Insulated stainless steel, passivated.
Insulation shall withstand 200°C environment.
Fastener - Stainless steel, passivated.
Option: Aluminum integral to cover.
Mating connectors: MIL-DTL-38999, series III.
Gasket shall be bonded to cover, or mechanically retained.
Rope shall rotate freely on fastener.
Fastener tensile strength: The protective cover and rope assembly shall withstand a dead weight
tensile load of 25 pounds applied to both axial and longitudinal directions. The load shall be applied at
the end of the rope assembly and held for 5 minutes. There shall be no separation of the rope
assembly from the protective cover or damage to the rope assembly. Both axial and longitudinal
directions shall be 25 pounds. The load shall be applied to the end of the rope.
4