MIL-DTL-38999/33E
Qualification. Qualification shall be in accordance with MIL-DTL-38999, except only the following
sequence of tests shall be required:
Examination of product
Coupling torque
Humidity
Salt spray (corrosion)
Fastener tensile strength (see requirement)
Altitude immersion.
For classes J and M only, temperature cycling and hydrolytic stability shall also be required.
Group A sampling inspection. Sampling for group A inspection shall be as specified in table I.
TABLE I. Group A sampling plan.
Lot size
Sampling size
1 to 13
100 percent
14 to 150
13 units
151 to 280
20 units
281 to 500
29 units
501 to 1,200
34 units
1,201 to 3,200
42 units
3,201 and up
54 units
Part or Identifying Number (PIN) example:
D38999/33
W
15
R
Specification sheet number
Class
(see requirements)
Shell size
Style
R - Rope
N - With rope and ring
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business