MIL-PRF-39012/128C
Leakage (pressurized connectors): Not applicable.
Insulation resistance: In accordance with MIL-STD-202, method 302, test condition B, 5,000 megohms
minimum.
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
1.5
2.0
Outer contact:
2.0
Not applicable
Resistance to test prod damage: Not applicable.
Corrosion (Salt spray): In accordance with MIL-STD-202 method 101, test condition B.
Voltage standing wave ratio (VSWR): Not applicable.
Dielectric withstanding voltage at sea level: In accordance with MIL-STD-202, method 301. 1,500 V
rms, minimum at sea level.
Connector durability: 500 cycles minimum at 12 cycles per minute maximum. The connector shall
meet mating characteristics and force to engage and disengage requirements.
Vibration, high frequency: In accordance with MIL-STD-202, method 204, test condition D.
Shock: In accordance with MIL-STD-202, method 213, test condition C.
Thermal shock: In accordance with MIL-STD-202, method 107, test condition B, except high
temperature shall be +85°C. High temperature shall be +200°C for connectors using +200°C cables.
Moisture resistance: In accordance with MIL-STD-202, method 106 (no measurements at high
humidity). Insulation resistance shall be at least 200 Megaohms within 5 minutes after removal from
humidity. Dielectric withstanding voltage shall be met. Voltages shall be applied at points suitable for
testing each individual insulator.
Corona level:
Voltage: 375 Volts, minimum.
Altitude: 70,000 feet
RF high potential withstanding voltage:
Voltage and frequency: 1000 V rms, tested at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
RF leakage: Not applicable.
RF insertion loss: Not applicable.
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business