MIL-PRF-39012/23B
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Connector shall be mounted in mounting hole specified on figure 1
with mating end capped. Test applicable to mounting seal of M39012/23-X001 only.
Air pressure: 30 psi.
Duration: 30 seconds minimum.
Insulation resistance: Method 302, test condition B of MIL-STD-202. 5,000 megohms minimum.
Contact resistance: In milliohms maximum.
After environment
Initial
Center contact
2.0
2.5
Outer contact (Silver)
.2
Not applicable
Outer contact (Nickel)
.4
Not applicable
Resistance to test prod damage: Not applicable.
Corrosion (salt spray): Method 101, test condition B of MIL-STD-202.
Voltage standing wave ratio (VSWR): Not applicable.
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 1,500 volts rms at sea level.
Corona level: Voltage 375 volts minimum.
Altitude 70,000 feet (4.437 kPa).
RF high potential withstanding voltage:
Voltage and frequency: 1,000 volts rms at 5 MHz.
Leakage current: Not applicable.
Contact durability: Insertion and withdrawal force 500 cycles minimum at 12 cycles/min maximum.
The mating force shall meet the mating characteristics requirements.
Vibration, high frequency: Method 204, test condition B of MIL-STD-202. No discontinuities.
Shock: Method 202 of MIL-STD-202.
Acceleration: 50 G's at 7 milliseconds.
No discontinuities permitted.
Temperature cycling: Method 102, test condition C of MIL-STD-202, except high temperature shall be
200°C.
Thermal shock: Not applicable.
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity. Dielectric
withstanding voltage shall be met.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business