MIL-PRF-39012/3H
REQUIREMENTS:
Designs and configurations: See figures 1, 3 and 4.
Force to engage and disengage:
Longitudinal force: Not applicable.
Torque: 6 inch-pounds (.68 Nm) maximum.
Coupling proof torque: Not applicable.
Inspection conditions: Coupling torque: 6 to 10 inch-pounds (.68 1.13 Nm).
Mating characteristics: In accordance with MIL-STD-348 and figure 2.
Center contact (socket):
Oversize test pin: .074 inch (1.88 mm) diameter minimum (nonclosed entry contacts only).
Insertion depth: .125 inch (3.17 mm) minimum.
Number of insertions: 1.
Insertion force test: Steel test pin diameter .066 inch (1.68 mm) minimum.
Test pin finish: 16 microinches (0.406 µm).
Insertion force: 2 pounds (8.90 N) maximum.
Withdrawal force test: Steel test pin diameter .063 inch (1.60 mm) maximum.
Withdrawal force: 2 ounces (.56 N) minimum.
Test pin finish: 16 microinches (0.406 µm).
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: Method 302 of MIL-STD-202, test condition B. 5,000 megohms minimum.
Center contact retention: (Applicable to captivated-center-contact connectors only.) 15 pounds (66.72
N) minimum axial force for all cables except RG400 and RG142; 6 pounds (26.69 N) minimum for
RG400 and RG142.
Corrosion (salt spray): Method 101 of MIL-STD-202, test condition B.
10
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.