MIL-PRF-39012/58H
RF leakage: -60 dB minimum, tested at frequency between 2 and 3 GHz.
RF insertion loss: .06 √ F (GHz) dB maximum tested at 3 and 6 GHz.
Group qualification: See table IV.
PIN: M39012/58 (dash number from table I or "B" number from table V).
TABLE IV. Group qualification and retention testing. 1/
Group
Submission and qualification of
Qualifies the following
any of the following connectors 2/
connectors
M39012/
M39012/
I
57-X009
57-X006
58-X009
X007
59-X009
X008
X009
X010
X030
58-X006
X007
X008
X009
X010
X030
59-X006
X007
X008
X009
X010
X030
See notes at end of table.
11
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business