MIL-PRF-49142/9D
Corona level:
Altitude: 70,000 feet (4.437 kPa).
Voltage: 200 V rms minimum.
RF high potential withstanding voltage:
800 V rms, between center conductor and intermediate conductor.
200 V rms, between intermediate conductor and outer conductor at 5 MHz to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force (for cable .200 inch (5.08 mm) to .325 inch (8.25 mm) outside dimension): 40
pounds (177.93 N) minimum.
Coupling mechanism retention force: Not applicable.
Rise time degradation: 400 picoseconds maximum. (Not applicable to connectors using twin conductor
cables.)
Connector durability: 500 cycles minimum at 12 cycles per minute maximum.
Part or Identifying Number (PIN): M49142/09- (dash number from table I). CAUTION: A NICKEL
PLATED BODY COMBINATION IS AVAILABLE. THIS COMBINATION IS NOT FOR USE IN
APPLICATIONS WHERE PASSIVE INTERMODULATION GENERATION (PIM) MAY BE A
CONCERN.
Group qualification: See table II.
Cross-reference of cables: See table III.
Retention of qualification: See table IV.