MIL-DTL-26500G
TABLE XII. Fluid immersion.
Sample
Test fluid
Test procedure
subgroup
specification
Immerse unmated connectors in fluid at 120° ± 3°C for 5 minutes.
MIL-PRF-7808
1
Remove connectors and allow to drain for 1 hour at room
temperature.
MIL-PRF-23699 Fluid shall be drained from all recesses.
2
Mate connectors and expose to 175° ± 3°C in air circulating oven
for 22 hours. Repeat procedure for a total of seven cycles.
Same as above except immerse in fluid at 85°C for 5 minutes and
3
MIL-PRF-5606
expose mated connectors to 104° ± 3°C in air circulating oven for
22 hours.
4
MIL-DTL-5624
Same as for MIL-PRF-7808 except fluid temperature shall be at
(Grade JP-5)
room temperature.
Glycol
5
Same as MIL-PRF-7808 except fluid temperature shall be
Alkaline cleaning 65° ± 3°C and connectors shall be mated during fluid immersion.
6
solution pH 10-12
7
MIL-PRF-5606
The unmated connectors shall be immersed in the fluid at room
temperature for 20 hours. Remove connectors and allow to drain
for 1 hour at room temperature. Fluid shall be drained from all
recesses.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor
personnel, these personnel need to contact the responsible packaging activity to ascertain packaging
requirements. Packaging requirements are maintained by the Inventory Control Point's packaging
activities within the Military Service or Defense Agency, or within the military service's system commands.
Packaging data retrieval is available from the managing Military Department's or Defense Agency's
automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not
mandatory.)
6.1 Intended use. The connectors covered by this specification are intended for use in electrical
control and power circuits of ground, rocket, missile, aircraft and space environments.
26
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business