MIL-PRF-39012/24D
Shock: Method 202 of MIL-STD-202.
Acceleration 50 G's at 7 milliseconds.
No discontinuities.
Thermal shock: Method 107, test condition C of MIL-STD-202 except low temperature shall be -55°C.
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity. Dielectric
withstanding voltage shall be met.
Cable retention force: Not applicable.
RF leakage: Not applicable.
Insertion loss: Not applicable.
PIN: M39012/24- (dash number from table I).
Changes from previous issue. Marginal notations are not used in this revision to identify changes with
respect to the previous issue due to the extent of the changes.
Referenced documents. In addition to MIL-PRF-39012, this document references the following:
MIL-STD-202
MIL-STD-348