MIL-PRF-39012/29H
Thermal shock: Method 107 of MIL-STD-202, test condition B, except test high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200° cables (see tables I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megaohms within 5 minutes after removal from humidity.
Corona Level:
Voltage - 375 volts rms, minimum.
Altitude - 70,000 feet (4.437 kPa).
RF high potential withstanding voltage:
Voltage and frequency: 1,000 volts rms at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force:
Noncrimp assemblies: 40 pounds (177.92 N), minimum.
Crimp assemblies:
10 pounds (44.48 N), minimum for cables .155- .189 inch (3.94 mm 4.80 mm) OD.
20 pounds ((88.96 N), minimum for cables .190-.229 inch (4.83 mm 5.82 mm) OD.
30 pounds (133.45 N), minimum for cables .230-.249 inch (5.84 mm 6.32 mm) OD.
40 pounds (177.92 N), minimum for cables .250 inch (6.35 mm) OD. and larger.
Coupling mechanism retention force: Not applicable.
RF Leakage: -60 dB minimum, tested at a frequency between 2 and 3 GHz.
Insertion loss: .18 dB maximum tested at 9 GHz.
.06
F (GHz) dB max tested at 3 GHZ to 6 GHz.
PIN: M39012/29 - (dash number from table I or "B" number from table III).
Group qualification: See table II.
11