MIL-PRF-39012/34B
Withdrawal force test: Steel test pin dia .052 maximum.
Withdrawal force 2 oz minimum.
Test pin finish 16 microinches.
-5
Hermetic seal: Leakage shall not exceed 1 x 10 cc/sec of tracer gas at atmospheric pressure.
Leakage (pressurized connectors): Connector mounted in mounting hole specified on figure 1 with
mating end capped. Test applicable to mounting seal only. Air pressure 30 psi. Duration: 30
seconds minimum.
Insulation resistance: Method 302, test condition B, MIL-STD-202. 5,000 megohms minimum.
Center contact retention:
6 lbs minimum axial force.
4 inch-ounces radial torque minimum.
Corrosion (salt spray): Method 101, test condition B, MIL-STD-202.
Voltage standing wave ratio (VSWR): Not applicable.
Connector durability: 500 cycles at 12 cycles/minute maximum. The connector shall meet the mating
characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms maximum.
Contact
Initial
After environment
Center contact
4.0
5.0
Outer contact
.2
Not applicable.
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 1,500 volts rms minimum at sea level.
Vibration, high frequency: Method 204, test condition C, MIL-STD-202.
Group qualification: See table II.
Shock: Method 213 of MIL-STD-202, test condition I.
Temperature cycling: Method 102, test condition C, MIL-STD-202, except test high temperature shall
be +200°C.
Thermal shock: Not applicable.
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona level:
Voltage 375 volts, minimum.
Altitude 70,000 feet.
RF high potential withstanding voltage:
Voltage and frequency: 1,000 volts rms at 5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.