MIL-PRF-39012/4F
Contact resistance: In milliohms maximum.
Initial
After environment
Center contact:
M39012/04-X001
4.0
5.0
Outer contact:
M39012/04-0001
.2
Not applicable
M39012/04-7001
.4
Not applicable
Center contact:
M39012/04-X002
1.0
1.5
M39012/04-X003
1.0
1.5
Outer contact:
M39012/04-0002
.2
Not applicable
M39012/04-0003
.2
Not applicable
M39012/04-7002
.4
Not applicable
M39012/04-7003
.4
Not applicable
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 2,500 volts rms minimum at sea level.
Vibration, high frequency: Method 204, test condition B, MIL-STD-202.
Shock: Method 213 of MIL-STD-202, test condition I.
Temperature cycling: Method 102, test condition C, MIL-STD-202 except high temperature shall be
85°C. High temperature shall be ± 200°C.
Thermal shock: Method 107 of MIL-STD-202, test condition B, except high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200°C cables (see table I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona level: Not applicable
RF high potential withstanding voltage:
Voltage and frequency: 1,500 volts rms at 5 MHz.
Leakage current: Not applicable.
Cable retention force: Not applicable.
Coupling mechanism retention force: Not applicable.
RF leakage: Not applicable.