MIL-PRF-39012/40J
Withdrawal force test:
Steel test pin diameter: .090 inch (2.29 mm), maximum.
Insertion depth: .125 inch (3.17 mm), minimum.
Test pin finish: 16 micro inches (0.406 µm).
Withdrawal force: 2 ounce (.56 N), minimum.
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: In accordance with MIL-STD-202, 5,000 mega ohms
minimum.
Center contact retention:
Axial force: 15 pounds (66.72 N) minimum, for all cables except M17/60-RG142 and M17/128-RG400
which shall be 6 pounds (26.69 N) minimum. Applicable to captivated center contacts only.
Radial torque: Not applicable.
Corrosion (salt spray): In accordance with MIL-STD-202 method 101, condition B.
Voltage standing wave ratio (VSWR): From 500 MHz to 11 GHz, or approximately 80 percent of the
upper cutoff frequency of the cable, whichever is lower; 1.30, maximum.
Swept frequency VSWR setup:
Item 6: VSWR shall be less than 1.015 +.005F (F in GHz).
Item 16: VSWR shall be less than 1.015 +.005F (F in GHz).
Second set of VSWR checkout procedure VSWR shall be less than 1.045 +.019F (F in GHz).
Group B inspection VSWR shall be less than 1.10 +.01F (F in GHz).
Qualification and group C inspection VSWR shall not exceed 1.15.
Connector durability: 500 cycles minimum at 12 cycles per minute maximum. The connector shall
meet mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
1.0
1.5
Outer contact (silver):
.15
Not applicable
Outer contact (nickel):
.30
Not applicable
Braid to body:
.05
Not applicable