MS90555G
Finish C (grounding assemblies)
Shell size |
Shell main keyway position (60 Hz and 400 Hz, see note 1) |
||||||
1 0 |
3 0 |
3 0 (see note 2) |
|||||
2 wire |
3 wire |
4 wire |
3 wire |
||||
120 v |
240 v |
120/240 v |
120/208 v |
240/416 v |
277/480 v |
450/480 v |
|
28 32 44 48 52 |
4 (120°) 4 (120°) 4 (120°) --- --- |
5 (135°) 5 (135°) --- --- --- |
4 (120°) 4 (120°) 4 (120°) 4 (120°) 4 (120°) |
4 (120°) 4 (120°) 4 (120°) 4 (120°) 4 (120°) |
5 (135°) 5 (135°) 5 (135°) 5 (135°) 5 (135°) |
6 (150°) 6 (150°) 6 (150°) 6 (150°) 6 (150°) |
--- --- 1 (60°) --- --- |
NOTES:
1. Discrimination of 60 Hz and 400 Hz assemblies is accomplished by alternate positioning of inserts.
See applicable insert drawing for keying.
2. For Navy ground support equipment use only. Arrangements 44-51, 44-52 and 44-56 are not applicable.
3. Shell main keyway positions 2 and 3 are not used.
FIGURE 2. Alternate keyway position - Continued.
Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.
Referenced documents. In addition to MIL-DTL-22992, this document references the following: MS14054
MS14055
MS14057
MS90563
MS90556
MS90565
MS90567
SAE-AS39029/49
7