MIL-DTL-12883/45D
TABLE I. Dash numbers and configurations.
Number
Contact
Dash number/socket
Contact
Mating
Polarization
configuration
size
of
designation
relay
type
contacts
M39029/101
mating end
wire barrel
1/ M83536/1-021,
I
-01
20
20
8
-553
/1-024, /2-021, /2-024
-02
20
20
8
-553
II
-03
20
20
8
-553
III
None
20
20
6
-553
M6106/38-002
-04
required
22
22
4
-552
20
20
6
-553
-05
II
22
22
4
-552
20
20
6
-553
-06
III
22
22
4
-552
1/ Reference M83536 for supersession data on M6106 relays.
Insertion and withdrawal force: The insertion and withdrawal forces shall be as specified in table II.
TABLE III. Insertion and withdrawal forces.
Condition
Test
M12883/45
-01 through -03
-04 through -06
9 lbf (40.0 newton)
10.0 lbf (44.5
Insertion force (max)
Initial
newton)
Withdrawal force (min)
.35 lbf (1.6 newton) .44 lbf (2.0 newton)
After 10 insertions and
11.0 lbf (48.9
11.7 lbf (52.0
Insertion force (max)
newton)
newton)
withdrawals, before
vibration
Withdrawal force (min)
.30 lbf (1.3 newton) .38 lbf (1.7 newton)
Insertion force (max)
11 lbf (48.9 newton) 11.7 lbf (52.0)
After vibration
Withdrawal force (min)
.30 lbf (1.3 newton) .38 lbf (1.7 newton)
Durability: Shall be in accordance with MIL-DTL-12883.
Vibration (sinusoidal): In accordance with MIL-STD-202, method 204, test condition G, except as
specified below:
a. The frequency range shall be varied logarithmically between the limits of 10 and 3000 HZ.
b. The procedure of method of 201 of MIL-STD-202 may be applied during 10-55 Hz band of the
vibration frequency range.
Vibration (random): In accordance with MIL-STD-1344, method 2005, test condition V, letter G, with a
duration of 15 minutes. The mating relay shall be used as the test gage.
Shock (mechanical): In accordance with MIL-STD-202, method 213, condition C, except peak value shall
be 200 g's.
6