MIL-DTL-27599D
c.
Receptacles should be located so as to minimize the amount of required cable bending.
When using series II connectors with large cables which must be bent at right angles, the
cables must have the right angle bend permanently established.
d. Series II connector should not be used with heavy jacketed cable and excessive overhang
moments, because of possible shell damage.
e. Series II connectors should not be used in areas of rough handling such as experienced near
engine removal, generators, support equipment, or portable equipment, etc.
f.
When mating series II connectors in areas of difficult visibility, care must be exercised to
make sure that all bayonet pins are engaged by the coupling ring, since it is possible to
engage only one bayonet pin and therefore only partially couple.
g. When mating series II connectors in areas of difficult visibility, care must be exercised to
make sure that connector plugs with pins are not coupled to receptacles with pins. This
situation will result in the contacts touching.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
c. Packaging requirements (see 5.1).
6.3 Qualification. With respect to products requiring qualification, awards will be made only for
products which are, at the time of award of contract, qualified for inclusion in Qualified Product List QPL
No.27599 whether or not such products have actually been so listed by that date. The attention of the
contractors is called to these requirements, and manufacturers are urged to arrange to have the products
that they propose to offer to the Federal Government tested for qualification in order that they may be
eligible to be awarded contracts or orders for the products covered by this specification. Information
pertaining to qualification of products may be obtained from the Defense Supply Center Columbus,
DSCC-VQ, 3990 East Broad Street, Columbus, Ohio 43218-3990. An online listing of products qualified
to this specification may be found in the Qualified Products Database (QPD) at https://assist.daps.dla.mil.
6.3.1 Copies of "Provisions Governing Qualification SD-6". Copies of "Provisions Governing
Qualification SD6" may be obtained upon application to Commanding Officer, Naval Publications and
Forms Center, 5801 Tabor Avenue, Philadelphia, PA 19120.
6.4 Definitions.
6.4.1 Scoopproof. Scoopproof means that because of the connector long shell design, it is impossible
for the mating plug connector to inadvertently be cocked into the mating receptacle and damage the pins
or electrically short the contacts.
6.5 Subject term (key word) listing.
Bayonet coupling
Series I
Series II
Intermateable
Fixed pin
Termination
Circuit closure