TABLE V. First article inspection - contact test sequence.
Contact sample numbers
Test
151-160
141-150
121-140
101-120
81-100
61-80
41-60
1-20
21-40
Requirement method no. 26 or
1 - 20
no. 26 or
no. 18 or
no. 26 or
no. 24 or
no. 22 or
no. 20 or
no. 18 or
no. 18 or
Inspection
paragraph paragraph no. 30
no. 30
no. 22
unplated
no. 30
no. 28
no. 26
no. 24
no. 22
no. 22
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
AWG
Group I (180 contacts)
through 3.4.5,
Visual and mechanical
X
X
X
X
X
X
X
X
X
X
inspection
3.7, and 3.8
Group II (20 sets)
Salt spray (corrosion)
X
Contact resistance
X
Low level circuit
X
3.6.15
resistance
X
X
Visual and mechanical
inspection
Group III (50 sets)
X
X
X
X
Contact separating
X
forces (plated contacts)
Crimp tensile strength 1/
X
X
X
X
X
Crimp tensile strength 1/
X
X
X
X
X
Group IV (20 contacts)
X
Contact separating
forces (unplated)
1/ Not applicable to solder type contacts.
NOTE: Wire size 18 through 26 AWG are used with contacts having a wire range of 18 to 26 AWG and wire sizes 22 through 30 AWG are used
with contacts having a wire range of 22 to 30 AWG.
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business