MIL-DTL-3650B
TABLE V. Group C inspection.
Examination or test
Requirement
Method
paragraph
paragraph
Subgroup 1 (unassembled connectors)
4.4.1
Visual and mechanical examination
3.1 to 3.2.9, incl table I and 4.4.1
Material
Design and construction
Physical dimensions 1/
3.1 and 3.3
4.4.1
Metal parts
3.3.1
4.4.1
Screw threads
3.3.2
4.4.1
Insulators
3.3.3
4.4.1
Gage tests for contacts
3.3.4
4.4.1.1
Subgroup 2 (assembled connectors)
3.5
4.4.4
Salt spray (corrosion)
1/ Only those dimensions related to piece parts (other than gage tests for
contacts) shall be checked (see 4.3.1.5.1.1.1).
TABLE VI. Sample size and acceptance number.
Acceptance number 1/
Number of connectors of a given
Sample
Subgroup 1
Subgroup 2
type produced during a month
size
1 to 1,000 incl
2
0
0
1/ For subgroup 1, see 4.3.1.5.1.1 to 4.3.1.5.1.1.2, inclusive, for subgroup 2, see
4.3.1.5.1.2.