MIL-DTL-83517A
4.4.1.3.1 Group B sampling plan. A sample of parts shall be randomly selected in accordance with
table VI. If one or more defects are found, the lot shall be screened for that particular defect and
defective parts removed. After screening and removal of defects, a new sample of parts shall be
randomly selected and subjected to all tests in accordance with table V. If one or more defects are found
in the second sample, the lot shall be rejected and shall not be supplied to this specification.
TABLE V. Group B inspection.
Inspection
Requirement
Test method
paragraph
paragraph
Force to engage/disengage
Coupling proof torque
Design and construction
Force to engage/disengage
Contact gaging
Permeability of nonmagnetic
materials
Insulation resistance
VSWR
TABLE VI. Group B Sampling Plan
Lot size
Sample size
VSWR sample
size
1
ALL
1
to
4
1
5
5
to
15
2
5
16
to
50
3
5
51
to
90
3
11
91
to
150
3
13
151
to
280
3
16
281
to
500
5
19
501
to
1,200
5
23
1,201
to
3,200
5
29
3,201
to
10,000
5
35
10,001
to
35,000
8
40
35,001
and over
4.4.1.3.2 Disposition of sample units. Sample units which have passed all the group B inspection may
be delivered on the contract or purchase order, if the lot is accepted. Any connector deformed or
otherwise damaged during testing shall not be delivered on the contract or order.