MIL-PRF-39012/16H
Voltage standing wave ratio (VSWR): From .5 to 4 GHz, or approximately 80 percent of upper cutoff
frequency of the cable, whichever is lower; 1.30, maximum.
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.015 + .005 F (F in GHz).
Item 16: VSVR shall be less than 1.015 + .005 F (F in GHz).
Second step of VSWR checkout procedure: VSWR shall be less then 1.045 + .019 F (F in GHz).
Group B inspection; VSWR shall be less than 1.1 +.01 F (F in GHz}.
Qualification and group C inspection: VSWR shall not exceed 1.15.
Connector durability: 500 cycles minimum, at 12 cycles per minute, maximum. The connector shall
meet the mating characteristics and force to engage and disengage requirements.
Initial: 5 pounds (22.24 N), maximum.
Final: 5 pounds (22.24 N) maximum; 1 pound (4.45 N), minimum.
Contact resistance: In milliohms, maximum:
Initial
After environment
Center contact
1.5
2.0
Outer contact (silver)
.2
Not applicable
Outer contact (nickel)
.4
Not applicable
Braid to body
.1
Not applicable
Dielectric withstanding voltage: Method 301 of MIL-STD-202, 1,500 volts rms, minimum at sea level.
Vibration, high frequency: Method 204 of MlL-STD-202, test condition B. No discontinuity permitted.
Shock: Method 213 of MIL-STD-202, test condition G.
Thermal shock: Method 107 of MIL-STD-202, test condition B, except test high temperature shall be
+85°C. High temperature shall be at +200°C for connectors using +200'C cables (see tables I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona Level:
Voltage: 375 volts rms, minimum.
Altitude: 70,000 feet (4.437 kPa).