MIL-PRF-39012/16H
TABLE I. Dash numbers, cross reference, and dimensions Continued.
4/ The superseded PIN is NOT acceptable for Government use.
5/ Cable to be used for the +200°C temperature cycling tests. This cable can be used for tests with the
approval of the Qualifying Activity.
6/ Cable to be used when performing test requiring cable except as in 5/ and 7/.
7/ These are not 50-ohm cables; therefore, when attached to the specified connectors, VSWR, RF,
leakage and insertion toss are not applicable.
8/ These connectors are assembled using the applicable crimp tool, to the specified cables stripped as
shown on figure 4.
9/ M22520/5-19 closure B or MS22520/5-05 closure A.
M22520/5-11 closure A.
M22520/5-57 closure A.
10/ M22520/5-19 closure A or M22520/5-07 closure A.
M22520/5-13 closure A.
M22520/5-59 closure A.
11/ M22520/5-41 closure B or M22520/5-05 closure B.
M22520/5-09 closure A.
12/ M22520/5-35 closure B or 22520/5-03 closure A.
13/ Complete connector assembly shall consist of a body, center contact, ferrule and assembly
instructions.
14/ Not to be used in Army equipment.
#
Dimensions are in inches. Metric equivalents are given for information only.
X
Denotes connector body plating material option. The only plating options allowable are Silver or
Nickel over brass in accordance with MIL-PRF-39012. Only connectors of the same materials shall
be mated to avoid dissimilar metal problems. CAUTION: A NICKEL PLATED BODY IS NOT FOR
USE IN APPLICATIONS WHERE PASSIVE INTERMODULATION GENERATION (PIM) MAY BE A
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business