MIL-PRF-39012/19H
Hermetic seat: Not applicable.
Leakage: Connector shall be mounted in mounting hole shown on figure 1 with mating end capped.
Test applicable to mounting seal only.
Air pressure - 30 Lbf/in2.
Duration - 30 seconds, minimum.
Insulation resistance:
Method 302 of MIL-STD-202, test condition B, 5,000 megohms, minimum.
Center contact retention: 6 pounds (26.69), minimum axial force. Applicable to captivated center contact
connectors only.
Corrosion (salt spray): Method 101 of MIL-STD-202, test condition B.
Voltage standing wave ratio (VSWR): From 500 to 4 GHz, or approximately 80 percent of upper cutoff
frequency of the cable, whichever is lower; 1.30, maximum.
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.015+ .005 F (F in GHz).
-
Item 16: VSWR shall be less than 1.015 + .005 F (F in GHz).
Second step of VSWR checkout procedure: VSWR shall be less than 1.045+.019 F (F in GHz).
Group B inspection: VSWR shall be less than 1.1+ .01 F (F in GHz).
Qualification and group C inspection: VSWR shall not exceed 1.15.
Connector durability: 500 cycles, minimum at 12 cycles per minute, maximum. The connector shall meet
the mating characteristics end force to engage and disengage requirements.
Contact resistance: In milliohms, maximum:
Initial
After environment
Center contact
1.5
2.0
Outer contact (silver)
.2
Not applicable
Outer contact (nickel)
.4
Not applicable
Braid to body
.1
Not applicable
Dielectric withstanding voltage: Method 301 of MIL-STD-202, 1,500 volts rms, minimum at sea level.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B. No discontinuity permitted.
Shock: Method 213 of MIL-STD-202, test condition G. No discontinuity permitted.