MIL-PRF-39012/19H
Thermal shock: Method 107 of MIL-STD-202, test condition B, except test high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200°C cables (see tables I and Ill).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona Level:
Voltage: 375 volts rms, minimum.
Altitude: 70,000 feet (4.437 kPa).
RF high potential withstanding voltage:
Voltage and frequency: 1,000 volts rms at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force:
Noncrimp assemblies: 40 pounds (177.92 N), minimum.
Crimp assemblies:
10 pounds (44.48 N), minimum for cables .155 - .189 inch (3.96 mm 4.80 mm) OD.
20 pounds (88.96 N), minimum for cables .190 - .229 inch (4.83 mm 5.82 mm) OD.
30 pounds (133.45 N), minimum for cables .230 - .249 inch (5.84 mm 6.32 mm) OD.
40 pounds (177.93 N), minimum for cables .250 inch (6.35 mm) OD - and larger.
Coupling mechanism retention force: Not applicable.
RF leakage: -55 dB minimum, tested at a frequency between 2 and 3 GHz.
Insertion loss: .2 dB maximum tested at 3 GHz.
PIN: M39012/19 (dash number from table I or "B" number from table III).
Group qualification:
See table II.