Leakage (pressurized connectors): Not applicable.
Insulation resistance: Method 302 of MIL-STD-202, test condition B. 5,000 megohms minimum.
Center contact retention: (Applicable to captivated-center-contact connectors only.) 15 pounds (66.72
N) minimum axial force for all cables except M17/128-RG400 and M17/60-RG142; 6 pounds (26.69 N)
minimum for M17/128-RG400 and M17/60-RG142.
Corrosion (salt spray): Method 101 of MIL-STD-202, test condition B.
Voltage standing wave ratio (VSWR): From 500 to 11 GHz, or approximately 80 percent of upper cutoff
frequency of the cable, whichever is lower; 1.30 maximum (1.45 max. to 11 GHz for X503, -X504,
-X513 and X514).
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.008 + .002 F (F in GHz).
Item 16: VSWR shall be less than 1.008 + .002 F (F in GHz).
Second step of VSWR checkout procedure: VSWR shall be less than 1.012 + .004 F (F in GHz).
Group B inspection: VSWR shall be less than 1.024 + .007 F (F in GHz).
Qualification and group C inspection: VSWR shall not exceed 1.08.
Connector durability: 500 cycles minimum at 12 cycles/minute maximum. The connector shall meet the
mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms maximum.
Initial
After environment
Center contact
1.0
1.5
Outer contact (silver)
.2
Not applicable
Outer contact (nickel)
.4
Not applicable
Braid to body
.05
Not applicable
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 2,500 volts rms minimum at sea level for
connectors using other than M17/128-RG400 and M17/60-RG142; 1,500 volts rms minimum for
connectors using M17/128-RG400 and M17/60-RG142.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B. No discontinuity permitted.
Shock: Method 213 of MIL-STD-202, test condition I. No discontinuity permitted.
Thermal shock: Method 107 of MIL-STD-202, test condition B, except test high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200°C cables (see table I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.