MIL-PRF-39012/5H
Voltage standing wave ratio (VSWR): From 500 to 11 GHz, or approximately 80 percent of upper
cutoff frequency of the cable, whichever is lower.
From 500 MHz to 9 GHz: 1.35 maximum.
From 9 to 11 GHz: 1.50 maximum.
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.008 + .002 F (F in GHz).
Item 16: VSWR shall be less than 1.008 + .002 F (F in GHz).
Second step of VSWR checkout procedure VSWR shall be less than 1.012 + .004 F (F in GHz).
Group B inspection VSWR shall be less than 1.024 +.007 F (F in GHz).
Qualification and group C inspection VSWR shall not exceed 1.08.
Connector durability: 500 cycles minimum at 12 cycles/minute maximum. The connector shall meet
the mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms maximum.
Initial
After environment
Center contact
2.5
3.0
Outer contact (silver)
.2
Not applicable
Outer contact (nickel)
.4
Not applicable
Braid to body
.05
Not applicable
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 2,500 volts rms minimum at sea level for
connectors using other than RG400 and RG142; 1,500 volts rms minimum for connectors using RG400
and RG142.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B. No discontinuity permitted.
Shock: Method 213 of MIL-STD-202, test condition I. No discontinuity permitted.
Thermal shock: Method 107 of MIL-STD-202, test condition B, except high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200°C cables (see table I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona level:
Voltage: 500 volts rms minimum.
Altitude: 70,000 feet (4.437 kPa).
9