MIL-PRF-39012/68D
Initial: 14 pounds (62.27 N), maximum.
Final:
14 pounds (62.27 N), maximum engage and disengage; 2 pounds (8.90 N) minimum
disengagement.
Contact resistance: In milliohms, maximum.
Initial
After environment
Center contact:
6.0
8.0
Outer contact:
1.0
1.5
Braid to body:
1
Not applicable
Dielectric withstanding voltage at sea level: In accordance with MIL-STD-202, method 301.
Cable group
V rms (at sea level)
I
750
II, IIa
1,000
Vibration, high frequency: In accordance with MIL-STD-202, method 204, test condition B.
Shock: In accordance with MIL-STD-202, method 213, test condition B.
Thermal shock: In accordance with MIL-STD-202, method 107, test condition B, except test high
temperature shall be +85°C. High temperature shall be +200°C for connectors using +200°C cables
(see tables I and III).
Moisture resistance: Not applicable.
Corona level:
Altitude: 70,000 feet (4.437 kPa).
Cable group
Volts, min.
I
185
II, IIa
250
6