MIL-PRF-39012/76D
REQUIREMENTS:
Dimensions and configuration: See figure 1 and MIL-STD-348.
Force to engage and disengage:
Longitudinal force: Not applicable.
Torque: 16 inch-ounces (.11 Nm), maximum.
Coupling proof torque: Not applicable.
Inspection conditions: Torque 35 to 50 inch-ounces (.25 to .35 Nm).
Mating characteristics: See MIL-STD-348.
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: In accordance with MIL-STD-202, method 302, test condition B, 1,000 megohms
minimum.
Center contact retention:
Axial force: 4 pounds (17.79 N), minimum axial force. Applicable to captivated center contacts only.
Radial torque: Not applicable.
Corrosion (salt spray): In accordance with MIL-STD-202 method 101, test condition B.
Voltage standing wave ratio (VSWR): From 500 MHz to 10 GHz, or approximately 80 percent of the
upper cutoff frequency of the cable, whichever is lower.
Cable group
VSWR
I
1.25 + 0.04 (F) GHz
II, IIa,
1.20 + 0.04 (F) GHz
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.05 +.0025F (F in GHz).
Item 16: VSWR shall be less than 1.05 +.0025F (F in GHz).
Second step of VSWR checkout procedure VSWR shall be less than 1.10 +.01F (F in GHz).
Group B inspection: VSWR shall be less than 1.08 +.017F (F in GHz).
Qualification and group C inspection: VSWR shall not exceed 1.15.
6
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business