MIL-DTL-12883/41F
Environmental:
Temperature range: Operating temperature range: -70ºC to +125 ºC.
Wire sealing: A resilient grommet is permanently bonded to the wire entry face of the socket so as
to provide moisture-sealing capabilities (see figure 1). Wire sealing range shall be as specified in
table II.
TABLE II. Wire sealing range.
Wire sealing range
Contact size
(mm)
.030 min to .054 max
22-22
(0.76 min to 1.37 max)
.040 min to .083 max
16-20
(1.02 min to 2.11 max)
.065 min to .109 max
16-16
(1.65 min to 2.77 max)
Mechanical:
Vibration (sinusoidal): In accordance with MIL-DTL-202, method 204, test condition G.
a. Except that the frequency range shall be varied logarithmically between the limits of 10 Hz
and 3,000 Hz.
b. Except that the procedure of method 201 of MIL-STD-202 may be applied during 10 Hz to
55 Hz band of the vibration frequency range.
c. Qualified mating relay shall be used as a test gauge.
Vibration (random): In accordance with mIL-STD-1344, method 2005, test condition V, letter G,
with a test duration 15 minutes. The mating relay shall be used as the test gage.
Shock (mechanical): In accordance with MIL-STD-202, method 213, condition C, except peak
value shall be 200 g's.
Insertion and withdrawal forces: The insertion and withdrawal forces of the relay and socket shall
be as specified as in table III.
10