4.6.2.5 Rejected lots. If an inspection lot is rejected after group A or group B inspection, the lot shall
not be supplied to the contract or purchase order. In cases where the defects are minor in nature, such
as smudged marking, the contractor may contact the qualifying activity and may be allowed to screen the
lot to remove defective parts or rework the lot. The qualifying activity can provide further guidance in
such situations.
4.6.3 Group A inspection. Group A inspection shall consist of the inspections specified on table IV in
the order shown.
4.6.3.1 Sampling plan (group A). A sample of parts shall be randomly selected from a production lot in
accordance with table V. If one or more defects are found, the lot shall be rescreened and defects
removed. After screening and removal of defects, a new sample of parts shall be randomly selected in
accordance with table V. If one or more defects are found in the second sample, the lot shall be rejected
and shall not be supplied to this specification.