MIL-PRF-39012/80F
Center contact retention:
Axial force: 6 pounds, minimum axial force. Applicable to captivated center contacts only.
Radial torque: Not applicable.
Salt atmosphere (corrosion): In accordance with MIL-STD-202 method 101, test condition B.
Voltage standing wave ratio (VSWR): From 500 MHz to 12.5 GHz (or 500 MHz to 18 GHz, if
applicable), or approximately 80 percent of the upper cutoff frequency of the cable, whichever is lower.
VSWR
Cable group
M17/133-RG405*
1.10 +0.01F (F in GHz)
M17/130-RG402*
1.10 +0.01F (F in GHz)
* VSWR values apply to all cable PIN's on these specification sheets even if not listed.
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.025 +.002F (F in GHz).
Item 16: VSWR shall be less than 1.025 +.002F (F in GHz).
Second step of VSWR checkout procedure VSWR shall be less than 1.080 +.005F (F in GHz).
Group B inspection: Use step 5, long cable method.
Qualification and group C inspection: Use step 5, long cable method.
Connector durability: 500 cycles minimum at 12 cycles per minute maximum. The connector shall
meet mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms, maximum.
After environment
Initial
Center contact:
4.0
6.0
Outer contact:
2.0
Not applicable
Outer cable conductor to body:
.5
Not applicable
NOTE: Five milliohms are permissible on passivated steel bodied connectors (outer cable
conductor to body only)..