MIL-PRF-39012/83G
Supplemental test requirements for qualification and group C inspection for category F connectors.
Six additional connectors shall be selected from the production lot and terminated to produce three
cable leads, twelve inches minimum, sixteen inches maximum. The three assemblies shall be
subjected to the following tests in sequence: VSWR, thermal shock, VSWR, and cable retention.
The following exceptions to the requirements apply to this supplemental test only:
VSWR of the cable assembly: From 0.5 to 18 GHz.
VSWR
VSWR (initial)
(after thermal shock)
Test cable assembly
M17/133-RG405 *
1.15 +.023F (F in GHz)
1.15 +.028F (F in GHz)
M17/130-RG402 *
1.10 +.023F (F in GHz)
1.10 +.025F (F in GHz)
* Values apply to all cable PINs on these specification sheets even if not listed.
Thermal shock: 10 cycles.
Group qualification: See table IV.
PIN: M39012/83 (dash number in table I or "B" number in table V).
PIN cross-reference: See table VI.