MIL-PRF-55339C
3.11 Insulation resistance. When adapters are tested as specified in 4.5.8 , the insulation
resistance shall not be less than that specified (see 3.1).
3.12 Voltage standing wave ratio (VSWR). When adapters are tested as specified in 4.5.9, the
VSWR shall not exceed that specified over the frequency range specified (see 3.1).
3.13 RF leakage. When adapters are tested as specified in 4.5.10, the total leakage shall not
exceed that specified (see 3.1).
3.14 RF insertion loss. When adapters are tested as specified in 4.5.11, the insertion loss shall not
exceed that specified (see 3.1).
3.15 Adapter durability. When adapters are tested as specified in 4.5.12, they shall show no
evidence of severe mechanical damage and the coupling device shall remain functional. Adapters
3.16 Dielectric withstanding voltage. When adapters are tested as specified in 4.5.13, there shall
be no evidence of breakdown.
3.17 Contact resistance. When adapters are tested as specified in 4.5.14, the contact resistance of
the center contact and outer contact shall be as specified (see 3.1).
3.18 Vibration. When adapters are tested as specified in 4.5.15, there shall be no electrical
interruptions exceeding 1 microsecond (µs), or as otherwise specified (see 3.1). There shall be no
evidence of visual mechanical damage after the test, and the contact resistance of the center contact
3.19 Shock (specified pulse). When adapters are tested as specified in 4.5.16, there shall be no
electrical interruptions exceeding 1 µs unless otherwise specified (see 3.1). There shall be no
evidence of visual or mechanical damage after the test, and the contact resistance of the center
contact shall not exceed the specified amount (see 3.1).
3.20 Thermal shock. After testing as specified in 4.5.17, there shall be no evidence of visual
mechanical damage to the adapter and it shall meet the dielectric withstanding voltage requirement
(see 3.16), and the contact resistance specified for the center contact shall not be exceeded (see 3.1
and 3.17).
3.21 Moisture resistance. When adapters are tested as specified in 4.5.18 , there shall be no
evidence of damage. They shall withstand the dielectric withstanding voltage specified (see 3.16),
and the insulation resistance shall not be less than that specified (see 3.11).
3.22 Corona level. When adapters are tested as specified in 4.5.19, at the altitude and voltage
specified (see 3.1), there shall be no evidence of sustained corona discharge.
3.23 RF high potential withstanding voltage. When adapters are tested as specified in 4.5.20, there
shall be no breakdown, and the leakage current specified shall not be exceeded (see 3.1).
3.24 Corrosion (Salt spray). When adapters are tested as specified in 4.5.21, there shall be no
exposure of the base metal on the interface or mating surface, and they shall meet the requirements
6